0
Articles   |    
The effect of load alteration on the biological and biomechanical performance of a titanium fiber-metal segmental prosthesis

The Journal of Bone & Joint Surgery.  1986; 68:118-126 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

The effect of overloading and underloading on tissue ingrowth into the porous-coated titanium segmental prosthesis was studied in a canine femoral model. The prosthesis has modular components that are connected by a conical coupling joint. One of the dog's hind legs was immobilized and suspended for three weeks using an external fixator to minimize loading and prevent weight-bearing, while the contralateral leg was allowed to bear weight freely, simulating an overloading situation. Five dogs reached the final study period of twelve weeks without complication. There were no significant differences between the non-weight-bearing and weight-bearing sides on radiographic assessments. However, the immobilized side had significantly higher stem-push-out strength and energy to failure. Bone ingrowth was variable, and a fibrous layer was commonly demonstrated at the prosthetic stem-bone interface. The orientation of the fibrous tissue was more organized, in a penetrating pattern, on the immobilized side. The mean concentration of titanium was insignificant in all tissue examined. Reduced implant loading for the porous-coated segmental bone prosthesis during the initial period of implantation was found to be beneficial as compared with an overloading situation in achieving intramedullary fixation.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Related Audio and Videos
    PubMed Articles
    Factors affecting modular acetabular ceramic liner insertion: a biomechanical analysis.
    Clinical orthopaedics and related research: Issue date- 2012 Feb
    Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis.
    The Journal of bone and joint surgery. British volume: Issue date- 2011 Oct
    Guidelines
    Results provided by:
    PubMed
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    02/16/2012
    MA - Beth Israel Deaconess Medical Center
    03/22/2012
    IL - Midwest Orthopaedics at Rush
    05/18/2012
    NY - SUNY-Downstate Medical Center
    05/18/2012
    NH - Concord Orthopaedics