0
Articles   |    
Contact pressures from an instrumented hip endoprosthesis

The Journal of Bone & Joint Surgery.  1989; 71:1378-1386 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case
text A A A

Abstract

A pressure-measuring Moore-type endoprosthesis was implanted in a seventy-three-year-old patient who had sustained a displaced fracture of the femoral neck. The measurement and telemetry of contact pressures in the hip began in the operating room, and data were acquired periodically for more than thirty-six months. Unexpectedly high localized contact pressures between the acetabular cartilage and the prosthesis were recorded. Early in the period of recovery, activities such as using a bedpan or performing isometric exercise produced pressures that were close to those recorded during normal walking. The highest pressure, eighteen megapascals, was recorded one year postoperatively, while the patient was rising from a chair. High pressures occurred in the superior and posterior aspects of the acetabulum.

Figures in this Article
    This article is only available in the PDF format. Download the PDF to view the article, as well as its associated figures and tables.
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Fluoroscopically guided hip capsulotomy: effective or not? A cadaveric study.
    Journal of orthopaedic trauma: Issue date- 2011 Apr
    Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs.
    The Journal of bone and joint surgery. British volume: Issue date- 2010 Nov
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    05/18/2012
    NY - SUNY-Downstate Medical Center
    01/04/2012
    PA - Penn State Milton S. Hershey Medical Center - Dept. of Orthopaedics & Rehabilitation
    03/07/2012
    KY - University of Louisville Dept. of Orthopaedic Surgery
    03/07/2012
    CA - SOAR Medical Group