0
Scientific Article   |    
The Influence of Glenohumeral Prosthetic Mismatch on Glenoid Radiolucent Lines Results of a Multicenter Study
Gilles Walch, MD; T. Bradley Edwards, MD; Aziz Boulahia, MD; Pascal Boileau, MD; Daniel Mole, MD; Patrice Adeleine, PhD
The Journal of Bone & Joint Surgery.  2002; 84:2186-2191 
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case

Abstract

Background: In shoulder arthroplasty, mismatch is defined as the difference in the radius or diameter of curvature between the humeral head and glenoid components. Recommendations for mismatch have not been substantiated scientifically. The purpose of this study was to evaluate the effect of mismatch on glenoid radiolucent lines.

Methods: The results of 319 total shoulder arthroplasties performed for the treatment of primary osteoarthritis were evaluated. All of the arthroplasties were performed with a single type of prosthesis (Aequalis; Tornier, Montbonnot, France) that included a cemented, all-polyethylene glenoid component. Three sizes of glenoid components and seven humeral head diameters were utilized. Radial mismatch was categorized as ≤4 mm, 4.5 to 5.5 mm, 6 to 7 mm, or >7 to 10 mm. Radiographs were evaluated at a mean of 53.5 months (range, twenty-four to 110 months) postoperatively. Glenoid radiolucent lines were scored with a scale ranging from 0 points for no radiolucency to 18 points for radiolucent lines exceeding 2 mm in six zones. Variance, linear contrasts polynomial, quadratic polynomial contrast statistical, and linear regression analyses were performed to evaluate the relationship between radial mismatch and glenoid radiolucent lines.

Results: A significant linear relationship was found between mismatch and the glenoid radiolucency score (p < 0.0001), with significantly lower (better) radiolucency scores associated with radial mismatches of >5.5 mm.

Conclusions: In this study of glenohumeral prosthetic mismatch ranging from 0 to 10 mm, the mismatch had a significant influence on the scores for the glenoid radiolucent lines, which were best when the radial mismatch was between 6 and 10 mm. The theoretical risk of prosthetic instability with larger mismatch values was not demonstrated within the range of mismatch values evaluated in this series.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    03/22/2012
    IL - Midwest Orthopaedics at Rush
    05/18/2012
    TX - University of North Texas Health Science Center
    01/04/2012
    LA - LSU Health Shreveport