0
Scientific Articles   |    
Two-Part Surgical Neck Fractures of the Proximal Part of the HumerusA Biomechanical Evaluation of Two Fixation Techniques
Sara L. Edwards, MD1; Nicole A. Wilson, MS2; Li-qun Zhang, PhD2; Steven Flores, MD1; Bradley R. Merk, MD1
1 Sara L. Edwards, MD Steven Flores, MD Bradley R. Merk, MD Department of Orthopaedic Surgery, Northwestern University, 645 North Michigan Avenue, Suite 910, Chicago, IL 60611
2 Nicole A. Wilson, MS Li-Qun Zhang, PhD Sensory Motor Performance Program, Rehabilitation Institute of Chicago, 345 East Superior Street, Room 1408, Chicago, IL 60611
The Journal of Bone & Joint Surgery.  2006; 88:2258-2264  doi:10.2106/JBJS.E.00757
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case

Abstract

Background: Successful internal fixation of fractures of the surgical neck of the humerus can be difficult to achieve because of osteopenia of the proximal aspect of the humerus. The purpose of this study was to compare the biomechanical stability of a proximal humeral intramedullary nail and a locking plate for the treatment of a comminuted two-part fracture of the surgical neck in a human cadaver model.

Methods: Twenty-four cadaveric humeri were instrumented with use of either a titanium proximal humeral nail (PHN) or a 3.5-mm locking compression plate for the proximal part of the humerus (LCP-PH). The specimens were matched by bone mineral density and were separated into four experimental groups with six humeri in each: PHN bending, LCP-PH bending, PHN torsion, or LCP-PH torsion. Comminuted fractures of the surgical neck were simulated by excising a 10-mm wedge of bone. Bending specimens were cyclically loaded from 0 to 7.5 Nm of varus bending moment at the fracture site. Torsion specimens were cyclically loaded to ±2 Nm of axial torque. The mean and maximum displacement in bending, mean and maximum angular rotation in torsion, and stiffness of the bone-implant constructs were compared.

Results: In bending, the LCP-PH group demonstrated significantly less mean displacement of the distal fragment than did the PHN group over 5000 cycles (p = 0.002). In torsion, the LCP-PH group demonstrated significantly less mean angular rotation than did the PHN group over 5000 cycles (p = 0.04). A significant number of specimens in the PHN group failed prior to reaching 5000 cycles (p = 0.04). The LCP-PH implant created a significantly stiffer bone-implant construct than did the PHN implant (p = 0.007).

Conclusions: The LCP proximal humeral plate demonstrated superior biomechanical characteristics compared with the proximal humeral nail when tested cyclically in both cantilevered varus bending and torsion. The rate of early failure of the proximal humeral nail could reflect the high moment transmitted to the locking proximal screw-bone interface in this implant.

Clinical Relevance: The high failure rate in torsion of the proximal humeral nail-bone construct is concerning, and, with relatively osteoporotic bone and early motion, the results could be poor.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Related Audio and Videos
    PubMed Articles
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    05/18/2012
    TX - University of North Texas Health Science Center
    05/18/2012
    NY - SUNY-Downstate Medical Center
    03/07/2012
    CA - SOAR Medical Group