Background: Early reports on modern ceramic-on-ceramic total hip replacements have demonstrated excellent clinical and radiographic results with few cases of catastrophic failure, which, in the case of earlier designs, often had been caused by implant fracture. Several reports, however, have noted the presence of audible squeaking. The purpose of the present study was to determine the incidence of squeaking in association with the use of this bearing couple.

Methods: During the period from March 2003 to May 2005, three surgeons performed 159 total hip arthroplasties in 143 patients with use of a ceramic-on-ceramic bearing. One hundred and forty-nine hips (131 patients) were available for review after at least one year of follow-up. These patients were followed prospectively with use of the modified Hospital for Special Surgery hip score and a patient-administered questionnaire. Additionally, a control group of sixty hips (forty-eight patients) with a metal-on-polyethylene bearing was matched to the ceramic group on the basis of age, sex, and body mass index to compare the incidence of squeaking and other noises. Radiographic evaluations were performed according to previously established criteria.

Results: Fourteen (10.7%) of 131 patients described an audible squeak during normal activities. However, squeaking was reproducible clinically in only four patients, and only one patient complained of squeaking before being presented with the questionnaire. The average Hospital for Special Surgery score improved from 19.8 preoperatively to 38.4 at the time of the latest follow-up, indicating excellent clinical results. Ninety-five percent of the patients had a satisfaction score of =8 of 10. Three hips dislocated. One of those three hips squeaked and was revised because of recurrent dislocations. One patient was considering revision because of squeaking. In the matched metal-on-polyethylene cohort, there were no cases of squeaking.

Conclusions: The squeaking hip is a phenomenon that is unique to total hip replacements with hard-on-hard bearings. The incidence of squeaking in association with ceramic-on-ceramic bearings may be higher than previously reported as <1% of the patients in the present study reported this finding before being queried. The causes and implications of squeaking are yet to be determined. The use of hard-on-hard bearings offers many advantages in terms of wear reduction, especially for young and active patients. Nonetheless, patients considering ceramic-on-ceramic bearings should be counseled with regard to this phenomenon.

Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $30
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org
    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe




    Related Articles
    Related Cases
    Related Content
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Clinical Trials
    Readers of This Also Read...
    jbjs jobs
    02/16/2012
    MA - Beth Israel Deaconess Medical Center
    01/04/2012
    LA - LSU Health Shreveport
    03/22/2012
    IL - Midwest Orthopaedics at Rush
    05/18/2012
    TX - University of North Texas Health Science Center