0
Articles   |    
Forces Required to Initiate Sliding in Second-Generation Intramedullary Nails*
DEB A. LOCH, M.S.†; RICHARD F. KYLE, M.D.†; JOAN E. BECHTOLD, PH.D.†; MICHAEL KANE, M.D.†; KIMBERLY ANDERSON, M.S.†; ROBERT E. SHERMAN, PH.D.†, MINNEAPOLIS, MINNESOTA
View Disclosures and Other Information
Investigation performed at the Orthopaedic Biomechanics Laboratory, Midwest Orthopaedic Research Foundation at Hennepin County Medical Center, Minneapolis
J Bone Joint Surg Am, 1998 Nov 01;80(11):1626-31
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case

Abstract

Second-generation intramedullary nails, which allow the fixation screw that is placed in the femoral head to slide distally and thus allow compression of the fracture of the femoral neck, have become a popular option for the treatment of ipsilateral fractures of the femoral neck and shaft. However, the sliding characteristics of the screw within the barrel of the nail or the side-plate have not been assessed biomechanically, to our knowledge. The goal of the current study was to investigate the forces required to initiate sliding of the proximal screw in intramedullary devices and to compare these forces with those required to initiate sliding of hip screws. The loading configuration simulated the typical angle of 135 degrees between the intramedullary nail and the proximal screw. The forces required to initiate sliding of the proximal screw, with the screw extended fifty-one, seventy-six, eighty-six, and 102 millimeters beyond the proximal end of the barrel, were measured for three different types of second-generation intramedullary nails (Recon, ZMS, and Gamma), a sliding compression hip screw, and an intramedullary hip screw, and these forces were then compared.With each amount of extension of the screw, the hip screws required lower forces to initiate sliding than did the second-generation intramedullary devices. Of the second-generation devices, the Gamma nail required the highest forces to initiate sliding; the Recon and ZMS nails required 20 to 40 percent lower forces compared with the Gamma nail. None of the devices jammed in any of the loading configurations that were tested. When the extension of the screw was increased, higher forces were required to initiate sliding.CLINICAL RELEVANCE: Since sliding allows continued compression of the fracture, surgeons should be aware that, compared with hip screws, the second-generation nails that we tested required higher loads to initiate sliding and to generate subsequent compression of the fracture.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $35
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org

    References

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe





    Related Content
    The Journal of Bone & Joint Surgery
    JBJS Case Connector
    Topic Collections
    Hip
    Related Audio and Videos
    Clinical Trials
    Readers of This Also Read...
    JBJS Jobs
    04/16/2014
    Ohio - OhioHealth Research and Innovation Institute (OHRI)