0
Scientific Articles   |    
Polyethylene Wear and Acetabular Component Orientation
Shantanu Patil, MD; Arnie Bergula, BS; Peter C. Chen, PhD; Clifford W. ColwellJr., MD; Darryl D. D'Lima, MD
View Disclosures and Other Information
The authors did not receive grants or outside funding in support of their research or preparation of this manuscript. They did not receive payments or other benefits or a commitment or agreement to provide such benefits from a commercial entity. One or more commercial entities paid or directed, or agreed to pay or direct, benefits to a research fund, foundation, educational institution, or other charitable or nonprofit organization with which the authors are affiliated or associated.

The Journal of Bone and Joint Surgery, Incorporated
J Bone Joint Surg Am, 2003 Nov 01;85(suppl 4):56-63
5 Recommendations (Recommend) | 3 Comments | Saved by 3 Users Save Case

Abstract

Background: Polyethylene wear contributes substantially to both periprosthetic osteolysis and aseptic loosening after total hip arthroplasty. Acetabular component orientation has been shown to affect the range of motion of the hip as well as contact stresses. A series of studies was designed to test the hypothesis that acetabular component orientation can affect the magnitude and direction of polyethylene wear.

Methods: A finite-element model was used to compute contact stresses during a normal gait cycle. Wear at the end of each gait cycle was calculated with use of the sliding-distance-coupled finite-element formulation. The wear that was calculated with use of finite-element analysis was validated by comparison with the findings of hip wear simulator studies with the acetabular liner oriented to simulate 45° and 55° of abduction. In a clinical study, fifty-six patients who underwent sixty hip arthroplasties with use of a single prosthetic design were followed for as long as five years. Radiographs were analyzed to measure the abduction angle of the acetabular component and polyethylene wear.

Results: The finite-element analysis predicted increased peak contact stresses with an increased abduction angle and reduced peak contact stresses with an increased anteversion angle. Linear wear rates ranging from 0.036 to 0.045 mm/million cycles were also predicted, and increased acetabular abduction angles were predicted to be associated with higher linear wear rates. In the hip wear simulator studies, significantly different wear rates were found between the cups with acetabular abduction angles of 45° and 55° (mean, 17.2 compared with 21.7 mg/million cycles; p < 0.01). In the clinical study, radiographic analysis revealed significant correlation between the acetabular abduction angle and the linear polyethylene wear rate. A 40% increase in mean linear polyethylene wear was seen in cups with an abduction angle of =45°. The direction of wear was more medial (by 9.4°) in cups with an abduction angle of <45°.

Conclusion: All three studies presented here underlined the importance of optimizing the position of the acetabular component. Careful attention to acetabular position may help to minimize wear.

Figures in this Article
    Sign In to Your Personal ProfileSign In To Access Full Content
    Not a Subscriber?
    Get online access for 30 days for $35
    New to JBJS?
    Sign up for a full subscription to both the print and online editions
    Register for a FREE limited account to get full access to all CME activities, to comment on public articles, or to sign up for alerts.
    Register for a FREE limited account to get full access to all CME activities
    Have a subscription to the print edition?
    Current subscribers to The Journal of Bone & Joint Surgery in either the print or quarterly DVD formats receive free online access to JBJS.org.
    Forgot your password?
    Enter your username and email address. We'll send you a reminder to the email address on record.

     
    Forgot your username or need assistance? Please contact customer service at subs@jbjs.org. If your access is provided
    by your institution, please contact you librarian or administrator for username and password information. Institutional
    administrators, to reset your institution's master username or password, please contact subs@jbjs.org

    References

    Accreditation Statement
    These activities have been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education (ACCME) through the joint sponsorship of the American Academy of Orthopaedic Surgeons and The Journal of Bone and Joint Surgery, Inc. The American Academy of Orthopaedic Surgeons is accredited by the ACCME to provide continuing medical education for physicians.
    CME Activities Associated with This Article
    Submit a Comment
    Please read the other comments before you post yours. Contributors must reveal any conflict of interest.
    Comments are moderated and will appear on the site at the discretion of JBJS editorial staff.

    * = Required Field
    (if multiple authors, separate names by comma)
    Example: John Doe





    Related Content
    The Journal of Bone & Joint Surgery
    JBJS Case Connector
    Topic Collections
    Hip
    Related Audio and Videos
    PubMed Articles
    Clinical Trials
    Readers of This Also Read...
    JBJS Jobs
    01/08/2014
    Pennsylvania - Penn State Milton S. Hershey Medical Center
    01/22/2014
    Pennsylvania - Penn State Milton S. Hershey Medical Center
    10/04/2013
    California - Mercy Medical Group